N/A - Apartment Building Fire, NONE


Vt. State Police - 2:40 pm Mon Nov 6th, 2006

On 11/05/06 this officer, Det./Sgt. Fred Cornell, and Inv.

Scott Adnams from the Division of Fire Safety conducted a origin and cause investigation of this scene. Through the scene investigation the area of origin of this fire was found to be in the first floor ceiling / second floor rear apartment bathroom floor. Investigation showed that a steam fed pipe from the furnace ran through this area to a junction in the area of origin. This location had a floor joist which rested within less than 1 inch of this pipe. The fire cause was most likely due to the pyrolysis (chemical decomposition of a compound by application of heat alone, this often precedes combustion) of the joist over time and eventually ignition of this material. This fire was ruled accidental.

INCIDENT: Apartment Building Fire
CASE #: 06A206320
TROOPER: Det./Sgt. Thomas Williams STATION: Rockingham
CONTACT#: (802)875-2112
DATE/TIME: 11/05/06 1600 hrs.
LOCATION (specific): 57 Main St. Richford, VT.
VIOLATION: NONE
ACCUSED: N/A
AGE:
CITY, STATE OF RESIDENCE:
VICTIM: Multiple AGE:
CITY, STATE OF RESIDENCE: Richford, VT.

Relevant Address(es):
Richford, VT 05476 (Set as Local)